To date, we have no information about building permits in 2025
Aug 14, 2014
Description: Use as a single family dwelling
- Permit #: USE2014-03266
Aug 12, 2014
Description: Original permit description:(com2013-23677) interior demolition category ii/ structural alterations/ interior work 1,730 sq. ft. - new interior build-out, new 2x4 stud walls @ 16" o.c., drywall, trim, insulation (r-20 walls, r-49 roof), new 2x10 floor joists @ 16" o.c., new staircase w/ hangers (7 3/4" r, 10" t, 3' w), sub flooring. new int. doors (12) - same size/ location. demo (500 sf) of non-bearing interior walls, doors, trim, plaster and debris. 3rd floor - fl joints replaced. exterior work - roofing, gutter and downspouts, (4) exterior doors same size/location and 20 windows same size/location as per plans/code. install new windows and doors as per plans on file and per code elevation certificate on file. first flood is 1.5 feet above the bfe. no mechanicals in basement. electrical panel(s) only on first floor or above.
- Permit #: COM2014-16926
Apr 9, 2014
Description: Non-structural alterations install (1) 40,000 btu gas furnace & install (1) 60, 000 btu as per code. * notice to proceed * install (2) new hvac units on rear roof as per plans on file. install vent/exhaust pipes as per plans and per code. *electric and gas by others
- Permit #: COM2014-05409
Apr 7, 2014
Description: Install 200 amp service. install 20 new circuits. install 8 low voltage as per code.
- Permit #: COM2014-05752
Apr 4, 2014
Description: Reconstruct waste and water for 4 toilets, 1 shower, 4 vanities, 1 kitchen sink, bar sink, 1 washing machine. install new gas lines for 1-40,000 btu, furance 1-60,000 btu furnace, and 1-40,000 btu range. install 1 65 gal eletric water heater. install 3/4 pressure reducing valve and 3/4 back flow preventer. install new 3/4'' water main. install new sump pump. all work done per code. hvac and electric by others
- Permit #: COM2014-06010
Mar 28, 2014
Description: Notice to proceed: construct 12 x 12 ft. wood deck on upper rear elevation as per drawings on file and per code with wrought iron metal railings
- Permit #: COM2014-05633
Dec 31, 2013
Description: *per chap ntp* scrape, spot point and repaint brick facade as per plans
- Permit #: COM2013-28041
Nov 13, 2013
Description: Interior demolition category ii/ structural alterations/ interior work 1,730 sq. ft. - new interior build-out, new 2x4 stud walls @ 16" o.c., drywall, trim, insulation (r-20 walls, r-49 roof), new 2x10 floor joists @ 16" o.c., new staircase w/ hangers (7 3/4" r, 10" t, 3' w), sub flooring. new int. doors (12) - same size/ location. demo (500 sf) of non-bearing interior walls, doors, trim, plaster and debris. 3rd floor - fl joints replaced. exterior work - roofing, gutter and downspouts, (4) exterior doors same size/location and 20 windows same size/location as per plans/code. install new windows and doors as per plans on file and per code elevation certificate on file. first flood is 1.5 feet above the bfe. no mechanicals in basement. electrical panel(s) only on first floor or above.
- Permit #: COM2013-23677
Lancaster St Fire Incident History
To date, we have no information about fire incidents in 2025
26 Dec 2019
Building fires
Property Use —
1 or 2 family dwelling
Area of Origin —
Roof surface: exterior
First Ignition —
Exterior roof covering or finish
Heat Source —
Heat from direct flame, convection currents
17 May 2014
Water vehicle fire
Property Use —
Dock, marina, pier, wharf
Area of Origin —
Cooking area, kitchen
Heat Source —
Spark, ember or flame from operating equipment
24 Mar 2001
Structure fire, other (conversion only)
Property Use —
1 or 2 family dwelling
Area of Origin —
Cooking area, kitchen
First Ignition —
Cooking materials, including edible materials
Heat Source —
Radiated, conducted heat from operating equipment
02 Feb 2001
Structure fire, other (conversion only)
Property Use —
Specialty shop
Area of Origin —
Bedroom - < 5 persons; included are jail or prison
Heat Source —
Spark, ember or flame from operating equipment
1623 Lancaster St incidents registered in FEMA
(Federal Emergency Management Agency)
To date, we have no information about incidents registered in FEMA in 2025
07 Mar 2012
Power line down
Property Use —
Residential street, road or residential driveway
24 Aug 2007
Chemical hazard (no spill or leak)
Property Use —
1 or 2 family dwelling
Lancaster St Incidents registered in FEMA
(Federal Emergency Management Agency)
To date, we have no information about incidents registered in FEMA in 2025
07 Mar 2012
Power line down
Property Use —
Residential street, road or residential driveway
24 Sep 2011
Carbon monoxide incident
Property Use —
1 or 2 family dwelling
03 Jul 2010
Hazardous condition, other
Property Use —
Residential street, road or residential driveway
07 Feb 2010
Hazardous condition, other
Property Use —
Street, other
Properties Nearby
Street Address | Residens/Landlords | |
---|---|---|
1621 Lancaster St, Baltimore, MD 21231-3425
|
Historic Dream Homes LLC, Eliza E Findlay | |
1710 Lancaster St, Baltimore, MD 21231-3411
|
Margaret Homan, Michael R Homan | |
1711 Lancaster St, Baltimore, MD 21231-3412
|
Fell's Point Residents Association, LLC, Christopher G Chute | |
1712 Lancaster St, Baltimore, MD 21231-3411
|
Ann Bergin, Michael T Geraghty | |
1713 Lancaster St, Baltimore, MD 21231-3411
|
Jessica L Jacob, Ann K Williams | |
1717 Lancaster St, Baltimore, MD 21231-3411
|
Harriette W Bode, Joseph J Bode | |
Nancy Cheng, Joani Christensen | ||
1804 Lancaster St, Baltimore, MD 21231-3506
|
Vincent Culotta, Joanne Cusick | |
1806 Lancaster St, Baltimore, MD 21231-3506
|
Amy J Shearer |