Building Permits
To date, we have no information about building permits in 2025
Aug 18, 2005
Description: Seismic bracing calculations.
- Contractor: Guardian South Inc
- Permit #: 05043-10000-02510
Jul 14, 2005
Description: Plumbing ti. sized on 1.2 psi/100 feet. 73/53 high/low psi per plan.
- Contractor: Abramian, Edick
- Permit #: 05042-20000-17674
Apr 22, 2005
Description: New flag pole.--30'-0" max. high.
- Permit #: 05020-10000-01348
Apr 22, 2005
Description: Ti- add nonbearing partitions to create a breakroom.
- Contractor: Smith Scott Massion
- Permit #: 05016-10000-07107
Mar 16, 2005
Description: Propose addition to(e) warehouse of creating new mezzanine (10,070sf).
- Permit #: 05014-70000-00860
Feb 28, 2005
Description: Install ventilation system for fire pump room. note: per david chan, building plan check engineer, only fire dampers are required at openinigs/duct penetration at ceiling of fire pump room.
- Contractor: Blake Air Conditioning And Service Co Inc
- Permit #: 05044-10000-01933
Feb 22, 2005
Description: Install (n) 22' high steel storage racks within warehouse under permit 03010-10000-04717.
- Contractor: Pollard Trevor S
- Permit #: 04016-10000-25072
Feb 9, 2005
Description: Supplemental permit for pcis # 03010-10000-04717: t.i. interior nonbearing partition wall to add one fire pump room.
- Contractor: Marc Studios
- Permit #: 03010-10003-04717
Jan 27, 2005
Description: Fire sprinkler central station monitor
- Permit #: 05041-90000-01820
Dec 7, 2004
Description: New 5'6" concrete block wall to create recylcing enclosure and trash enclosures as per engineers detail: max height = 8' and max linear lenth = 59'6"
- Contractor: Marc Studios
- Permit #: 04020-70000-04801
Dec 3, 2004
Description: Revision to permit #03010-10000-04717 to include lot tie affidavit and meets and bounds description. for alley vacation refer to doc. vac-e1400796 (see comments)
- Permit #: 03010-70002-04717
Nov 19, 2004
Description: Revision to permit 03010-10000-04717 to revise floor plan at second floor and add (2) new exterior opening on west wall, correct parking count and revise occupant load count.
- Contractor: Smith Scott Massion
- Permit #: 03010-20001-04717
Jul 15, 2004
Description: Installation of a 1500 gpm fire pump and an esfr fire sprinkler system for high piled rack storage. 8-inch fire service, rp backflow preventer is not required. the 1500 gpm fire pump is required to be enclosed in an 1-hour fire rated construction.
- Contractor: Guardian South Inc
- Permit #: 04043-10000-00919
Jun 2, 2004
Description: New 2-story tilt up warehouse building
- Permit #: 03010-10000-04717
May 26, 2004
Description: Prepare for pad - grading only. 4500 cy fill, 150 c.y. cut, import = 4350 c.y.
- Contractor: Aliano Giuseppe
- Permit #: 03030-10000-03265
23rd St Fire Incident History
To date, we have no information about fire incidents in 2025
22 Jul 2019
Outside rubbish, trash or waste fire
Property Use —
Street or road in commercial area
Area of Origin —
Highway, parking lot, street: on or near
14 Jul 2019
Trash or rubbish fire, contained
Property Use —
Street, other
Area of Origin —
Outside area, other
First Ignition —
Rubbish, trash, or waste
Heat Source —
Match
19 Mar 2019
Outside rubbish, trash or waste fire
Property Use —
Street or road in commercial area
28 Dec 2018
Outside rubbish fire, other
Property Use —
Street, other
Area of Origin —
Outside area, other
First Ignition —
Upholstered sofa, chair, vehicle seats
Properties Nearby
Street Address | Residens/Landlords | |
---|---|---|
Kevin Bennett | ||
Asie Properties, LLC, REVE CLOTHING, INC | ||
Marisol Acevedo, Gonzalez A Flores | ||
Susana Desantos, Veronica Ponce | ||
Josefina J Chavez, Santiago Ramirez | ||
Yvonne Ali, Aisha Bahar | ||
CHRIS JEAN CORP, CUT & PLUS SERVICE, INC | ||
GLOBAL COOLING, INC, MERMELADAS VICTORIA, INC |