Building Permits
To date, we have no information about building permits in 2025
Jun 10, 2011
Description: Request for permit to remove 1tree from property as shown on drawing (plat). must remove all debris within 24 hours of tree removal. call 301-258-6338 ivr system for inspection upon completion code 2030 see attached sheet for further instructions
- Parcel #: 160900835934
- Permit #: PI-S110074
Feb 18, 2011
Description: Enlarge window as show on plans. call 301-258-6338 to schedule the following inspections: framing #2015 final #2030 when alterations, repairs or additions requiring a permit occur the dwelling unit shall be provided with smoke alarms located as required for new dwellings; the smoke alarms shall be in every sleeping area, in the area immediately outside of each sleeping area, and at least one smoke detector on each level. for those areas undergoing construction or alteration, the required smoke detectors shall be a/c hardwired with battery back-up. in existing spaces that are not part of the construction/alteration, the required detectors may be battery operated. in all areas of new construction and any altered areas that have sufficient demolition to facilitate wiring, the required detectors shall be interconnected. approved as noted on plans and attached comment sheet.
- Parcel #: 160900835934
- Permit #: PI-B101039
Jan 25, 2011
Description: Construct wall, add cabinets,new wash/dryer outlets in basement.. call 301-258-6338 to schedule the following inspections: electrical rough-in #2127 framing/close-in #2015 final electric #2025 final building #2030 note: sleeping areas below grade are not permitted without a code conforming emergency escape window or side hinged door to the exterior of the dwelling. when alterations, repairs or additions requiring a permit occur the dwelling unit shall be provided with smoke alarms located as required for new dwellings; the smoke alarms shall be in every sleeping area, in the area immediately outside of each sleeping area, and at least one smoke detector on each level. for those areas undergoing construction or alteration, the required smoke detectors shall be a/c hardwired with battery back-up. in existing spaces that are not part of the construction/alteration, the required detectors may be battery operated. in all areas of new construction and any altered areas that have sufficient demolition to facilitate wiring, the required detectors shall be interconnected. approved as noted on plans and attached comment sheet. call for all required inspections 301-258-6338
- Parcel #: 160900835934
- Permit #: PI-B110025
Sep 10, 2010
Description: Construct a 107 sq. ft. shed in rear yard. -shed shall be a minimum of 3 feet from all property lines. -shed shall be anchored. -shed shall be less than 15 feet in height. call 301-258-6338 to schedule the following inspections: final #2030 when alterations, repairs or additions requiring a permit occur the dwelling unit shall be provided with smoke alarms located as required for new dwellings; the smoke alarms shall be in every sleeping area, in the area immediately outside of each sleeping area, and at least one smoke detector on each level. for those areas undergoing construction or alteration, the required smoke detectors shall be a/c hardwired with battery back-up. in existing spaces that are not part of the construction/alteration, the required detectors may be battery operated. in all areas of new construction and any altered areas that have sufficient demolition to facilitate wiring, the required detectors shall be interconnected.
- Parcel #: 160900835934
- Permit #: PI-B100838
Jan 9, 2009
Description: As built sq. ft. 900 finish basement including homeowner electrical. inspector(s) may require wall coverings be removed to check for code compliance. call 301-258-6338 to schedule the following inspections: electrical rough-in #2127 framing/close-in #2015 final electric #2025 final building #2030 note: sleeping areas below grade are not permitted without a code conforming emergency escape window or side hinged door to the exterior of the dwelling. when alterations, repairs or additions requiring a permit occur the dwelling unit shall be provided with smoke alarms located as required for new dwellings; the smoke alarms shall be in every sleeping area, in the area immediately outside of each sleeping area, and at least one smoke detector on each level. for those areas undergoing construction or alteration, the required smoke detectors shall be a/c hardwired with battery back-up. in existing spaces that are not part of the construction/alteration, the required detectors may be battery operated. in all areas of new construction and any altered areas that have sufficient demolition to facilitate wiring, the required detectors shall be interconnected. approved as noted on plans and attached comment sheet.
- Parcel #: 160900835934
- Permit #: PI-B080978
May 9, 2008
Description: Request for pemit to replace furnace, a/c and coil. call 301-258-6338 ivr system for all required inspections see attached list for codes
- Parcel #: 160900835934
- Permit #: PI-M080007
Tulip Dr Fire Incident History
To date, we have no information about fire incidents in 2025
21 Feb 2019
Passenger vehicle fire
Area of Origin —
Engine area, running gear, wheel area
First Ignition —
Item First Ignited, Other
Heat Source —
Heat source: other
Tulip Dr Incidents registered in FEMA
(Federal Emergency Management Agency)
To date, we have no information about incidents registered in FEMA in 2025
30 Nov 2014
Hazardous condition, other
Property Use —
Street, other
04 Oct 2012
Gasoline or other flammable liquid spill
Property Use —
Street, other
20 Apr 2011
Building or structure weakened or collapsed
Property Use —
1 or 2 family dwelling
23 Jan 2011
Outside rubbish, trash or waste fire
Property Use —
1 or 2 family dwelling